Enhanced TDS
Identification & Functionality
- Additives Included
- Blend
- Yes
- Chemical Family
- Plastics & Elastomers Functions
- Polymer Name
- Product Code
- MITM16464
- Single Ingredient
- No
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Product Features and Benefits
- Easy processability
- Very good mechanical properties
- High abrasion resistance
- High friction resistance
- Stable modulus with moist
- Environment
- Remarkable physical resistance
- Lightest engineering polymers
- Low water absorption
- Very good chemical resistance
- High aging resistance
- Wide range of temperature use
Applications & Uses
- Plastics & Elastomers Processing Methods
- Processing Information
Machine General All extruders suitable for polyamides can run the 141 N120-S Screw Types Screws with three zones (feeding, compression and metering zones) are recommended
Length: 22 D - 28 D (25 D is optimal)
Compression ratio: 2.5 - 3.1Material Drying 141 N120-S is dried and packed with a moisture content of less than 0.10 %. If the packing has been damaged or left open for a long time (>2 hours), then the material has to be dried. Polyamides are sensitive to oxidation at temperatures > 80°C in the oxygen atmosphere.
Drying Settings - Air Dryer
- Temperature: max. 80°C
- Time: 4 - 8 hours
- Vacuum Dryer
- Temperature: max. 80°C
- Time: 2 - 4 hours
Lubrication 141 N120-S includes internal lubricants. However, the use of Zinc Stearate or Calcium Stearate can be helpful in case of process instability
Process (Recommended Basic Settings) Basic Machine Settings - Hopper zone 60 - 90°C
- Feeding zone 210 - 235°C
- Compression zone 220 - 250°C
- Metering zone 220 - 250°C
- Head 210 - 240°C
- Melt 205 - 240°C
Cooling Bath 15 - 30°C - Air Dryer
Properties
- Physical Form
- Soluble In
Regulatory & Compliance
- Certifications & Compliance
Principal Information
- Group Principal Number
- S000003
- Principal
Storage & Handling
- Storage Conditions
Agimid® 141N120-S NAT has to be stored in dry, indoor and safe facilities. It is highly recommended to run granules having reached the workshop temperature to prevent from moisture condensing on cold granules
Other
- ADR/RID/ADN Proper Shipping Name
- Not Applicable
- ADR/RID/ADN UN Number
- Not Applicable
- Appearance (SDS)
- Granules
- Color (SDS)
- Characteristic
- Flammable Nature (SDS)
- Non flammable
- IATA/ICAO Proper Shipping Name
- Not Applicable
- IATA/ICAO UN Number
- Not Applicable
- IMO/IMDG Proper Shipping Name
- Not Applicable
- IMO/IMDG UN Number
- Not Applicable
- Insoluble in (SDS)
- Water
- Item Number
- Odor (SDS)
- Mild
- Other Hazards
- If the product is handled or used at high temperature, contact with hot product or vapours may cause burns. At high concentrations, the vapours can be irritating to the respiratory system. Prolonged and repeated skin contact may cause reddening, irritation and dermatitis.
- USA/DOT UN Number
- Not Applicable
- Thermal Properties
Value Units Test Method / Conditions Heat Deflection Temperature 125.0 °C °C ISO 75 at 0.45 MPa Heat Deflection Temperature 45.0 °C °C ISO 75 at 1.85 MPa - Electrical Properties
Value Units Test Method / Conditions Dielectric Strength 23.0 kV/mm kV/mm ASTM D149 as dry state - Mechanical Properties
Value Units Test Method / Conditions Elongation at Break min. 100.0 % % ISO 527 Tensile Modulus 370.0 MPa MPa ISO 527 Tensile Strength at Break 36.0 MPa MPa ISO 527 - Physical Properties
Value Units Test Method / Conditions Density 1.04 g/cm³ g/cm³ ISO 1183 at 23°C Melting Point 183.0 °C °C ISO 11357-1 Water Absorption 1.6 % % Internal Method at 23°C, with 100% relative humidity Water Absorption 1.0 % % Internal Method at 23°C, with 50% relative humidity - SDS Physical and Chemical Properties
Value Units Test Method / Conditions Boiling Point (SDS) 314.0 °C °C Density (SDS) 1.02 g/L g/L Melting Point (SDS) 168.0-178.0 °C °C