Enhanced TDS
Identification & Functionality
- Agrochemical Functions
- Chemical Family
- Cleaning Ingredients Functions
- Fluids & Lubricants Functions
- Industrial Additives Functions
- Product Code
- MITM12708
- Technologies
- Product Families
Features & Benefits
- Industrial Additives Features
- Labeling Claims
Applications & Uses
- Application Area
- Compatible Polymers & Resins
- Compatible Substrates & Surfaces
- Fluids & Lubricants End Use
- Fluids & Lubricants Type
- Industrial Additives End Use
- Markets
- Applications
- Product Applications
- Preventol® D 7 CF is a copper-free formulation of isothiazolinones.
- Preventole D 7 CF is a microbicide containing a mixture of (1.5 % active) isothiazolinones.
- Preventol® D 7 CF has a broad specturm of activity, is water soluble and compatible with most raw materials.
- Preventol® D 7 CF will not adversely affect product physical properties or performance and should not impart odor or color to most final products.
- Preventol® D 7 CF is readily incorporated into formulation and is compatible with surfactants and emulsifiers regardless of their ionic nature.
- However, if higher temperatures (>104 °F / >40 C) or pH values >9 are likely to occur during the manufacturing process, the product should be added at the end of the process or to the finished product. In this case take care to distribute the preservative uniformly in order to ensure homogeneous mixture of the product in the water. Since the Preventole D 7 CF has a low viscosity, the product can be added directly or pre-dissolved in water.
- Preservation: Preventol® D 7 CF provides broad-spectrum microorganism control in water-based systems. Preventol® D 7 CF is non-foaming, water-based product that is readily biodegradable after appropriate dilution.
- Water Treatment Preventol® D 7 CF is effective against bacteria that cause fouling and corrosion in industrial cooling water systems. Not only is Preventol® D 7 CF effective in controlling planktonic organisms, but the product will also aid in the control of biofilms. Use of the appropriate level of biocide in the water system can help to maintain a sufficient water flow rate and heat exchange by reducing the microbial load in the system.
- Slime Prevention Preventol® D 7 CF is a broad spectrum bactericide including efficacy against slime forming bacteria. Slime forming bacteria are a major concern in industrial water systems because they can help with the formation of biofilms. The biocide can be added directly to the primary circuit, the machine chest or the headbox. If the system is extremely fouled, it is recommended that a shock treatment followed by a continuous at a lower dose rate. (See Direction for Use section for dosage levels) Badly fouled water systems should be cleaned prior to biocide treatment.
- To obtain reliable and reproducible results, homogeneous distribution in the materials to be protected must be ensured by taking suitable measures in production (stirring, agitating, etc.)
- As with any product, the use of this product must be tested (including field testing) prior to incorporating into finished product.
- Product Uses
For industrial use as preservative to inhibit the growth of bacteria, fungi in aqueous compositions (including pesticide formulations), polymer emulsions, fountain solutions, inks and photoplate processing, paper mill process water, recirculating cooling water systems, recirculating electrodesposition systems, commercial photoprocessing systems.
- Product Uses
It is a violation of Federal law to use this product in a manner inconsistent with its labelling. The following guidance is given as an approximation for each use pattern, but field-testing is recommended to achieve optimum effectiveness.
Application Dosage Level** Liquid Household Consumer, Industrial, Janitorial Products*** 0.04 - 0.15% Semi-Solid/Solid household Consumer, Industrial, Janitorial Products*** 0.04 - 0.15% Preservative for Aqueous Compositions*** 0.05 - 0.33% Textile Processing Chemicals*** 0.04 - 0.16% Paints and Coatings 0.043 - 0.16% Ultra Filtration Units and Non-Medical / Non-Potable Reverse Osmosis System*** 0.001 - 0.033% Control of bacteria and fungi in carbon beds 0.001 - 0.033% For Periodic RO membrane cleaning 0.40 - 1.0 lbs per 120 gallons of cleaning solution
Pigment and Mineral Slurries 0.043 - 0.167 % Adhesives and Tackifiers 0.043 - 0.167 % Polymer Emulsions 0.043 - 0.33 % Building Materials 0.043 - 0.167 % Paper Mill Process Water 0.44 - 1.5 lbs per ton (dry basis) of pulp or paper
Industrial Recirculating Process Water Systems***
Application Dosage Level**
Initial Dose Subsequent Dose 0.015 - 0.088 % Subsequent Dose 3.5 × 10⁻³ to 2.19 × 10⁻² % Industrial Wastewater Treatment Systems and Sewage Systems***
Application Dosage Level**
Initial Dose 0.015 - 0.088 % Subsequent Dose 3.5 × 10⁻³ to 2.19 × 10⁻² % Recirculating Cooling Water Systems***
Application Dosage Level**
For noticeably fouled systems - Initial Dose 0.015 - 0.088% Maintain Microbial Control 3.5 × 10⁻³ to 2.19 × 10⁻² % Brewery Pasteurizer and Can Warmer Systems***
Application Dosage Level**
For noticeably fouled systems - Initial Dose 0.015 - 0.091% Maintain Microbial Control 3.5 × 10⁻³ to 2.19 × 10⁻² % Oil & Gas Fields Injection Waters***
Application Dosage Level**
Initial Dose 58.0 - 116.8 lbs per 1000 barrels of water Maintain Microbial Control 23.5 - 58.0 lbs per 1000 barrels of water Hydraulic Fluids***
Application Dosage Level**
For the maintenance of a non-fouled system For noticeably fouled systems (Initial Dose) 0.103 to 0.180 % **For detailed dosage instructions see Preventol® D7 CF EPA Label.
***Not For Use in the State of California.
****Regardless of the means of incorporation of the biocide, the total concentration in the system should not exceed 2333 ppm Preventol® D7 CF.
Properties
- Physical Form
- Soluble In
Packaging & Availability
- Packaging Type
Principal Information
- Group Principal Number
- S000008
- Principal
Storage & Handling
- Storage Conditions
- Preventol® D 7 CF should be stored in the original sealed package.
- Since Preventol® D 7 CF is an aqueous solution, appropriate measures should be taken to ensure temperature does not exceed 104 °F/ 40 °C and does not freeze during the transport and storage.
Other
- Appearance
- Clear yellow-green to pale blue solution
- Color (SDS)
- Yellow
- IATA/ICAO Proper Shipping Name
- Corrosive liquid, acidic, organic, N.O.S.
- IATA/ICAO UN Number
- UN3265
- IMO/IMDG EmS Fire
- F-A
- IMO/IMDG EmS Spill
- S-B
- IMO/IMDG Proper Shipping Name
- Corrosive liquid, acidic, organic, N.O.S.
- IMO/IMDG UN Number
- UN3265
- Item Number
- Odor (SDS)
- Odorless
- Other Hazards
- None known
- Protect from Freezing
- No
- USA/DOT Emergency Response Guide Number
- 153
- USA/DOT Proper Shipping Name
- Corrosive liquid, acidic, organic, N.O.S.
- USA/DOT UN Number
- UN3265
- Chemical Properties
Value Units Test Method / Conditions pH 4.0-6.0 - 0.01 - Shelf Life & Stability
Value Units Test Method / Conditions Shelf Life 1.0 yr yr - Physical Properties
Value Units Test Method / Conditions Boiling Point 100.0 °C °C At 1013 Hpa Density 1.024 g/cm³ g/cm³ At 20°C - Material Composition
Value Units Test Method / Conditions Active Content 0.4 % % 2-methyl-4-isothiazolin-3-one MIT Active Content 1.1 % % 5-chloro-2-methly-4-isothiazolin-3-one CMIT - Application Information
Value Units Test Method / Conditions Dosage (Use Level) 0.043-0.167 % % Adhesives and Tackifiers Dosage (Use Level) 0.043-0.167 % % Building Materials Dosage (Use Level) 0.001-0.033 % % Control of bacteria and fungi in carbon beds Dosage (Use Level) 0.44-1.5 lbs/ton lbs/ton dry basis of pulp or paper Dosage (Use Level) 0.043-0.167 % % For direct addition to fouled system Dosage (Use Level) 0.015-0.091 % % For noticeably fouled systems - Initial Dose Dosage (Use Level) 0.4-1.0 lbs/120gal lbs/120gal For periodic RO membrane cleaning Dosage (Use Level) 0.1-0.3 % % Fountain solution concentrates Dosage (Use Level) 0.0035-0.0219 % % Industrial Recirculating Process Water Systems Dosage (Use Level) 0.0035-0.0219 % % Industrial Wastewater Treatment Systems and Sewage Systems Dosage (Use Level) 0.015-0.088 % % Industrial Wastewater Treatment Systems and Sewage Systems*** Dosage (Use Level) 0.015-0.088 % % Initial Dose Dosage (Use Level) 0.05-0.117 % % Initial dose- Noticeably fouled system Dosage (Use Level) 0.033-0.233 % % Initial Dose of Paint Components Dosage (Use Level) 0.015-0.088 % % Intermittent or Slug Feed Dosage (Use Level) 0.04-0.15 % % Liquid Household Consumer, Industrial, Janitorial Products *** Dosage (Use Level) 23.5-58.0 lbs/1000 barrels lbs/1000 barrels Maintain microbial control Dosage (Use Level) 0.0035-0.0219 % % Maintenance Dose Dosage (Use Level) 0.043-0.167 % % Metal Cleaning Fluids Dosage (Use Level) 0.026-0.116 % % Metal working Dosage (Use Level) 0.043-0.167 % % metal working solutions Dosage (Use Level) 58.0-116.8 lbs/1000 barrels lbs/1000 barrels Oil & Gas Fields Injection Waters Dosage (Use Level) 0.043-0.16 % % Paints & Coatings Dosage (Use Level) 0.1-0.3 % % Photo/photoplate Processing, Fountain Solutions, And Ink/ink Components Dosage (Use Level) 0.043-0.33 % % Polymer Emulsions Dosage (Use Level) 0.05-0.33 % % preservative for aqueous compositions Dosage (Use Level) 0.04-0.15 % % Semi-solid / Solid Household Consumer, Industrial, Janitorial Products Dosage (Use Level) 0.033-0.1 % % Subsequent Dose Dosage (Use Level) 0.04-0.16 % % Textile Processing Chemicals Dosage (Use Level) 0.001-0.033 % % Ultra Filtration Units and Non-Medical / Non-Potable Reverse Osmosis System *** - SDS Physical and Chemical Properties
Value Units Test Method / Conditions Autoignition Temperature (SDS) min. 1112.0 °F °F Boiling Point (SDS) 212.0 °F °F Density (SDS) 1.024 g/cm³ g/cm³ at 20°C Flash Point (SDS) min. 212.0 °F °F Closed Cup Melting Point (SDS) 30.0 °F °F Viscosity (SDS) 1.244 mPa.s mPa.s pH (SDS) 4.0-6.0 - pH (SDS) 4.0-6.0 - concentration:1%