Preventol® IT 14

Preventol® IT 14 is a preservative used in adhesives and sealants, fluids and lubricants, paints and coatings, printing and inks, and water treatment. It is applied in air washer systems, hydraulic oils and fluids, and metalworking fluids. Compatible with wood substrates, it functions as a preservative in fluids and industrial additives.

Principal: Lanxess MPP

Functions: Preservative, Preservative

End Uses: Fountain Solutions, Hydraulic Fluids, Metalworking Fluids, Polymer Emulsions

Compatible Substrates & Surfaces: Wood

Chemical Family: Chemical Mixtures & Blends

Features: Eliminates Slimes, Excellent Corrosion Inhibition, Foulant Inhibiting, Non Foaming

Enhanced TDS

Identification & Functionality

Features & Benefits

Applications & Uses

Application Area
Compatible Substrates & Surfaces
Fluids & Lubricants End Use
Fluids & Lubricants Type
Industrial Additives End Use
Markets
Applications
Product Uses

It is a violation of Federal law to use this  Preventol® IT 14 in a manner inconsistent with its labeling.

Applications Dosage Levels**
Paints and Coatings

0.0044 – 0.0225 %

Pigment and Mineral Slurries

0.0044 – 0.0225 %

Adhesives and Tackifiers

0.0044 – 0.0225 %

Polymer Emulsions

0.0044 – 0.045 %

Metalworking Fluids – Tankside

 
Initial Dose for noticeably fouled systems

0.0056 – 0.012 %

Maintenance Dose

0.0022 – 0.012 %

Building Materials

0.0044 – 0.0225 %

Fountain Solutions, Ink, Ink components and photoplate processing chemicals 0.10 – 1.0 %
Acidic fountain solutions 0.20 – 0.50 %
Basic fountain solutions 0.50 – 0.80 %
Paper Mill Process Water

0.048 – 0.170 product per ton (dry basis) of pulp/paper

Recirculating Cooling Water Systems

 
Initial Dose for noticeably fouled systems

0.0012 – 0.0073 %

Maintenance Dose

0.0003 – 0.0018 %

Industrial Recirculating Process Water Systems

 
Initial Dose

0.0015 – 0.0088 %

Subsequent Dose

0.0003 – 0.0017 %

 

Applications Dosage Levels**

Industrial Wastewater Treatment Systems and Sewage Systems

 
Initial Dose

0.0015 – 0.0088 %

Subsequent Dose

0.0004 – 0.0022 %

Liquid Household Consumer, Industrial, Janitorial Products

0.0043 – 0.0157 %

Semi-solid / Solid Household Consumer, Industrial, Janitorial Products

0.0043 – 0.0157 %

Preservative for aqueous composition

0.005 – 0.0357 %

Treatment of Electrodeposition Paint Components

0.0036 – 0.025 %

Supplemental Tankside Dosing of Electrodeposition System

 
Initial Dose (Note: Preventol® IT 14 Preservative should not exceed 0.0245 %)

0.0070 – 0.0245 %

Subsequent Dose

0.0035 – 0.010 %

Ultra Filtration Units and Reverse Osmosis System

0.0001 – 0.0036 %

Reverse Osmosis membranes

 
Continuous or batch feed

0.0001 – 0.0035 %

Periodic Cleaning

0.0043 – 0.0107 %

Brewery Pasteurizer and Can Warmer Systems (Preventol® IT 14 max: 0.0248 %)

 
Initial Dose for noticeably fouled systems

0.0012 – 0.0073 %

Maintenance Dose

0.0003 – 0.0018 %

Hydraulic Fluids  
Initial Dose for noticeably fouled systems

0.0103 – 0.0185 %

Maintenance Dose

0.0071 – 0.0111 %

Oilfield Injection Waters

 
Initial Dose

6.1 – 12.5 lbs per 1000 barrels of water

Maintenance Dose (e.g. weekly)

2.4 – 6.2 lbs per 1000 barrels of water

Air Washer Intermittent Dosing

 
Initial Dose

0.0024 – 0.0065 %

Maintenance Dose

0.0011 – 0.0018 %

Air Washer – Continuous Dosing

 
Initial Dose

0.0024 – 0.0065 %

Maintenance Dose

0.0011 – 0.0018 %

Recirculating Electrodeposition systems – Tankside Addition

 
Initial Dose

0.0071 – 0.0245 %

Subsequent Dose

0.0035 – 0.106 %

 

Applications Dosage Levels**

Metal Cleaning Fluids

 
Metal Cleaning Concentrate
For direct addition to the fouled system

Final In Use-Dilution fluid: 0.0044 – 0.0244 %
0.0044 – 0.0244 % (every 3–4 weeks)

Commercial Photoprocessing Systems
Initial Dose for noticeably fouled systems

0.0042 – 0.0106 %

Maintenance Dose

0.0022 – 0.0042 %

Commercial Photoprocessing Concentrate

Final In Use-Dilution products: 0.0004 – 0.150 %

Preservative for Wood and Wood Products

 
Treat Pressure Treatment Solutions
Under extreme mildew conditions

0.0023 – 0.071 %
0.0334 % maximum

   

** For detailed dosage instructions see Preventol® IT 14 Preservative EPA Label

Product Uses

For the use in the preparation of stabilized isothiazolinone-based biocidal products.

Product Applications
  • Preventol® IT 14 Preservative is a microbicide containing a mixture of (14 % active) isothiazolinones.
  • Preventole IT 14 Preservative has a broad specturm of activity, is water soluble and compatible with most raw materials.
  • Preventol® IT 14 Preservative will not adversely affect product physical properties or performance and should not impart odor or color to most final products.
  • Preventol® IT 14 Preservative can be incorporated at any stage of the production process but is best added in the initial stage.
  • However, if higher temperatures (>104 °F / >40 C) or pH values >9 are likely to occur during the manufacturing process, the product should be added at the end of the process or to the finished product. In this case take care to distribute the preservative uniformly in order to ensure homogeneous mixture of the product in the water. Since the Preventole IT 14 Preservative has a low viscosity, the product can be added directly or pre-dissolved in water.
  • Preservation Preventole IT 14 Preservative provides broad-spectrum microorganism control in water-based systems. Preventol® IT 14 Preservative is non-foaming, water-based product that is readily biodegradable after appropriate dilution.
  • Water Treatment Preventole IT 14 Preservative is effective against bacteria that cause fouling and corrosion in industrial cooling water systems. Not only is Preventol® IT 14 Preservative effective in controlling planktonic organisms, but the product will also aid in the control. Use of the appropriate level of biocide in the water system can help to maintain a sufficient water flow rate and heat exchange by reducing the microbial load in the system.
  • Slime Prevention Preventol® IT 14 Preservative is a broad spectrum bactericide including efficacy against slime forming bacteria. Slime forming bacteria are a major concern in industrial water systems because they can help with the formation of biofilms. The biocide can be added directly to the primary circuit, the machine chest or the headbox. If the system is extremely fouled, it is recommended that a shock treatment followed by a continuous at a lower dose rate. (See Direction for Use section for dosage levels) Badly fouled water systems should be cleaned prior to biocide treatment.
  • To obtain reliable and reproducible results, homogeneous distribution in the materials to be protected must be ensured by taking suitable measures in production (stirring, agitating, etc.).
  • As with any product, the use of this product must be tested (including field testing) prior to incorporating into finished product.

Properties

Physical Form
Soluble In

Packaging & Availability

Principal Information

Group Principal Number
S000008
Principal

Storage & Handling

Storage Conditions
  • Preventol® IT 14 should be stored in the original sealed package.
  • Since Preventol® IT 14 Preservative is an aqueous solution, appropriate measures should be taken to ensure temperature does not exceed 104° F / 40 °C and does not freeze during the transport and storage.

Other

Appearance
Yellow / yellow-greenish to amber colored clear solution
Appearance (SDS)
Liquid
Color (SDS)
Amber
IATA/ICAO Proper Shipping Name
Corrosive liquid, toxic, N.O.S. (one and 2-methyl-isothiazol-3-)
IATA/ICAO UN Number
UN2922
IMO/IMDG EmS Fire
F-A
IMO/IMDG EmS Spill
S-B
IMO/IMDG Proper Shipping Name
Corrosive liquid, toxic, N.O.S. (one and 2-methyl-isothiazol-3-)
IMO/IMDG UN Number
UN2922
Item Number
Odor (SDS)
Slight
Other Hazards
Corrosive to the respiratory tract.
Oxidizing Properties (SDS)
Not oxidizing
Protect from Freezing
No
TDG Canada Proper Shipping Name
Corrosive liquid, toxic, N.O.S. (one and 2-methyl-isothiazol-3-)
TDG Canada UN Number
UN2922
Temperature Control
Yes
USA/DOT UN Number
Not Applicable
Application Information
ValueUnitsTest Method / Conditions
Dosage (Use Level)0.2-0.5 %%Acidic fountain solutions
Dosage (Use Level)0.0044-0.0225 %%Adhesives and Tackifiers
Dosage (Use Level)0.0024-0.0065 %%Air Washer -Continuous Dosing
Dosage (Use Level)0.0011-0.0018 %%Air Washer Intermittent Dosing
Dosage (Use Level)0.5-0.8 %%Basic fountain solutions
Dosage (Use Level)0.0003-0.0018 %%Brewery Pasteurizer and Can Warmer Systems
Dosage (Use Level)0.1-1.0 %%Building Materials
Dosage (Use Level)0.0004-0.15 %%Commercial Photoprocessing Concentrate
Dosage (Use Level)0.0022-0.0042 %%Commercial Photoprocessing Systems
Dosage (Use Level)0.048-0.17 /t/tdry basis, of pulp or paper, Paper Mill Process Water
Dosage (Use Level)0.0044-0.0244 %%every 3 - 4 weeks
Dosage (Use Level)0.0103-0.0185 %%Hydraulic Fluids
Dosage (Use Level)0.0015-0.0088 %%Industrial Recirculating Process Water Systems
Dosage (Use Level)0.0001-0.0036 %%Industrial ultra filtration or reverse osmosis system
Dosage (Use Level)0.0015-0.0088 %%Industrial Wastewater Treatment Systems and Sewage Systems
Dosage (Use Level)0.0022-0.012 %%Initial Dose for noticeably fouled systems
Dosage (Use Level)0.0043-0.0157 %%Liquid Household Consumer, Industrial, Janitorial Products
Dosage (Use Level)0.0044-0.0225 %%Maintenance Dose
Dosage (Use Level)0.0044-0.0244 %%Metal Cleaning Concentrate
Dosage (Use Level)0.0056-0.012 %%metal working solutions
Dosage (Use Level)6.1-12.5 lbs/1000 barrelslbs/1000 barrelsOilfield Injection Waters
Dosage (Use Level)0.0044-0.0225 %%Paints & Coatings
Dosage (Use Level)0.2-0.5 %%Photo/photoplate Processing, Fountain Solutions, And Ink/ink Components
Dosage (Use Level)0.0044-0.045 %%Polymer Emulsions
Dosage (Use Level)0.005-0.0357 %%preservative for aqueous compositions
Dosage (Use Level)0.0334 %%Preservative for Wood and Wood Products
Dosage (Use Level)0.0023-0.071 %%Preservative for Wood and Wood Products, Treat Pressure Treatment Solutions
Dosage (Use Level)0.0012-0.0073 %%Recirculating Cooling Water Systems
Dosage (Use Level)0.0071-0.0245 %%Recirculating Electrodeposition systems - Tanksdie Addition
Dosage (Use Level)0.0001-0.0035 %%Reverse Osmosis membranes
Dosage (Use Level)0.0043-0.0157 %%Semi-solid / Solid Household Consumer, Industrial, Janitorial Products
Dosage (Use Level)0.0004-0.0022 %%Subsequent Dose
Dosage (Use Level)0.0036-0.025 %%Treatment of Electrodeposition Paint Components
Dosage (Use Level)0.0035-0.01 %%Ultra Filtration Units and Reverse Osmosis System
Chemical Properties
ValueUnitsTest Method / Conditions
pH1.0-4.0-undiluted
Material Composition
ValueUnitsTest Method / Conditions
Active Content14.0 %%Total active isothiazolinone (CMIT / MIT) liquid formulation
Physical Properties
ValueUnitsTest Method / Conditions
Boiling Point100.0 °C°C
Density1.3 g/cm³g/cm³At 20°C
Storage Temperature14.0-104.0 °F°F
SDS Physical and Chemical Properties
ValueUnitsTest Method / Conditions
Boiling Point (SDS)100.0 °C°CAt 1013 Hpa
Decomposition Temperature (SDS)min. 55.0 °C°C
Density (SDS)1.3 g/cm³g/cm³at 20°C
Flash Point (SDS)min. 100.0 °C°CClosed Cup
Vapor Pressure (SDS)0.075 mm Hgmm HgAt 22°C
pH (SDS)1.0-4.0-
Shelf Life & Stability
ValueUnitsTest Method / Conditions
Shelf Life1.0 yryr